Page 53 - Dell PowerEdge R620 Technical Guide
P. 53

Table 32 lists power supply specifications for the PowerEdge R620.



          Specification                      1100W DC             1100W AC            750W AC           495W AC
          Current consumption                   32A                12A–6.5A            10A–5A           6.5A–3A
                                                                             1
                                                                                                1
                                                                                                                  1
          Supply voltage                  -48V to -60V DC       100–240VAC          100–240VAC        100–240VAC
          Frequency                             N/A                50/60Hz            50/60Hz           50/60Hz
                                                                                            2
                                                                                        2843
          Heat dissipation (BTU/hr max)         4416                 4100                   3             1908
                                                                                        2891
          1 Auto-ranging
          2
           Titanium efficiency
          3
           Platinum efficiency



            Table 33 details the environmental specifications for the R620. For additional information about
            environmental measurements for specific system configurations, see
            Dell.com/environmental_datasheets.



            Fresh Air: temperature, humidity, altitude de-rating
            Continuous      10°C to 35°C (50°F to 95°F) at 10% to 80% relative humidity with 26°C (78.8°F) maximum
            operation       dew point (maximum wet bulb temperature). De-rate maximum allowable dry bulb
                            temperature at 1°C per 300m above 950m (1°F per 547 ft above 3117 ft).

            Expanded        When operating in the expanded temperature range, system performance may be impacted,
            operation       and ambient temperature warnings may be reported on the LCD and in the System Event
                            Log.
                            ≤ 10% of annual operating hours: 5°C to 10°C and 35°C to 40°C (with no direct sunlight on
                            the equipment) at 5% to 85% relative humidity with 26°C dew point (maximum wet bulb
                            temperature). Outside the standard operating temperature (10°C to 35°C), the system can
                            operate down to 5°C or up to 40°C for a maximum of 10% of its annual operating hours. For
                            temperatures between 35°C and 40°C (95°F to 104°F), de-rate maximum allowable dry bulb
                            temperature by 1°C per 175m above 950m (1°F per 319 ft above 3117 ft).
                            ≤ 1% of annual operating hours: –5°C to 5°C and 40°C to 45°C (with no direct sunlight on
                            the equipment) at 5% to 90% relative humidity with 26°C dew point (maximum wet bulb
                            temperature). Outside the standard operating temperature (10°C to 35°C), the system can
                            operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours. For
                            temperatures between 40°C and 45°C (104°F to 113°F), de-rate maximum allowable dry bulb
                            temperature by 1°C per 125m above 950m (1°F per 228 ft above 3117 ft).
                            Expanded operation restrictions:
                              No cold startup below 5°C
                              Maximum altitude for the operating temperature must be 3050m (10,000ft)
                              Redundant power supplies required
                              Not supported:
                               -  Express Flash PCIe SSD
                               -  GPU
   48   49   50   51   52   53   54   55   56   57   58